Datalink Kit L - Silvus Modem 2x2

Hardware Installation

  1. First of all, to access the expansion bay, read Expansion Bay Access - Hardware Installation section of this manual.

  2. Screw the modem against the plate with four screws M2 x 0.4 x 10.

    Hardware Silvus 2x2 installation - Step 2

  3. Screw the switch on the opposite side with the switch support and two mushroom bolts M3 x 5.

    Hardware Silvus 2x2 installation - Step 3

  4. Attach the switch connector.

    Hardware Silvus 2x2 installation - Step 4

  5. Connect the modem to the switch as indicated in the following figure:

    Hardware Silvus 2x2 installation - Step 5

  6. Connect the switch to RF3 and RF4.

    Hardware Silvus 2x2 installation - Step 6

  7. Place the plate in the PCS and connect the indicated modem connectors to the bay connector, ethernet and RF2 (switch and modem were previously connected).

    Hardware Silvus 2x2 installation - Step 7

  8. Attach the PCS to the pole according to Pole Mount Installation - Hardware Installation section of this manual (do not close the expansion bay yet).

  9. Fix both antennas to the holder with the knobs.

    Important

    If the user desires to tilt an antenna, ignore this step and read the Adjustable Antenna Mount - Hardware Installation section of this manual.

    Hardware Silvus installation 2x2 - Step 9

  10. Join the holder to the pole with the wall bracket.

    Hardware Silvus installation 2x2 - Step 10

  11. Wire the antennas. In case of using a Veronte T28 with the PCS, the wiring is different.

    Wiring with only PCS
    (Diagram not scaled)

    Wiring with PCS and T28
    (Diagram not scaled)

Tip

Do not close the PCS until all configurations are finished.

Silvus radio configuration

To know how to do a basic configuration of the Silvus radio, visit Silvus radio configuration - Integration examples section of 1x Hardware Manual.

However, an additional configuration is required when working with a PCS instead of the GND unit of Veronte Autopilot 1x.

  • Networking. LAN Settings

    LAN Settings panel air unit

    LAN Settings panel PCS

    • Virtual IP: Enable or Disable the Secondary IP address for the radio. Enable
    • Virtual IPv4 Address: Set the secondary IP address for the radio. The user can set any IP address, we have chosen 192.168.96 for the radio connected to the air unit and 192.168.95 for the radio linked to the PCS.
    • Virtual IPv4 Netmask: Netmask for the Secondary IP address, e.g. 255.255.255.0.
    • Virtual IPv4 Gateway: Gateway for local network to allow radio to connect to the internet. 192.168.8.1 is set because it is the IP address of the PCS router.

Silvus radio configuration on PC

To be able to access the StreamScape GUI of the radios once connected to the PCS, check that the Network & Internet settings of the PC are as shown in the following screenshots.

Ethernet settings 1
Ethernet settings 2

Note

This configuration is the same whether the PCS is connected via wifi or ethernet.

Silvus radio configuration in autopilot

To configure an Autopilot 1x for a Silvus radio, visit External radios - Integration examples section of 1x PDI Builder user manual.


© 2026 Embention. All rights reserved.